Glow-worm Fault Code F.68 — Diagnose and Fix
Fault code F.68 on a Glow-worm boiler indicates overheat. Flow temperature exceeded the safety limit. Check pump operation, system pressure, and that heating valves are opening. A limescaled heat exchanger is the top cause in hard-water areas. Here is the correct diagnostic order UK Gas Safe engineers follow before ordering parts.
Step-by-step method
1. Confirm the F.68 lockout
Cycle the boiler off at the fused spur for 60 seconds, restore power and press the reset button. If F.68 returns within 5 minutes, proceed with diagnosis. Intermittent F.68 usually points to a sensor or connection, not the PCB.
2. Check pressure and condensate first
Every fault-code diagnosis starts here: system pressure 1.0–1.5 bar cold, condensate pipe unfrozen and draining, gas supply proven at another appliance. These three account for ~60% of lockouts.
3. Test the component F.68 points at
Flow temperature exceeded the safety limit. Check pump operation, system pressure, and that heating valves are opening. A limescaled heat exchanger is the top cause in hard-water areas.
4. Reset and test-fire
After any component test, purge the gas line, restore all covers (interlocks matter), press reset and observe a full ignition cycle. Confirm flame current with a multimeter on the flame sense wire (typically 1–8 µA DC).
5. Call a Gas Safe engineer for parts
Any gas-side work on a Glow-worm requires Gas Safe registration. Have the fault code, boiler GC number and serial to hand — engineers can pre-order the right part before attending.
Frequently asked questions
Can I reset a Glow-worm F.68 myself?+
Yes — press and hold the reset key for 5 seconds. If F.68 returns, the underlying fault is still present and needs diagnosis.
How much does fixing F.68 cost?+
£120–£280 typical, depending on part. PCBs are £180–£320 fitted; sensors £60–£100. Get a fixed-price quote — refuse hourly for diagnostic-only work.
Is F.68 covered by boiler warranty?+
Yes if within the Glow-worm manufacturer warranty period AND the boiler has valid annual services logged. Missed services void most warranties.