How to Drain a Central Heating System — UK Method

Draining a UK central heating system is a 30-minute job with the right hose routing. Here is the trade method for sealed and open systems.

Need parts for this job?
Trade-priced hose pipe in the Plumber.Parts catalog — next-day delivery.
Shop parts

Step-by-step method

1. Turn off boiler and cool

Programmer off, wait 30 minutes. Turn off gas at emergency valve.

2. Locate drain-off cock

Usually on the lowest radiator return, or a dedicated drain-off point on ground floor pipework. Small brass square nipple with hose barb.

3. Attach hose and route outside

Garden hose over drain-off. Route to outside gully or drain. Downhill flow all the way.

4. Open drain-off + bleed screws

Open drain-off with a spanner. Open bleed screws on top-floor radiators to admit air. System drains in 15–25 minutes.

5. Refill and dose

Close drain-off. Open filling loop until pressure 1.2 bar. Bleed rads top down. Dose Fernox F1 inhibitor via a radiator or F&E tank.

Frequently asked questions

Do I need to drain to change one radiator?+

No — closing both radiator valves is enough. Full drain only for pipework changes, boiler swap, or full flush.

How long to refill a system?+

25 minutes for a 3-bed house. Watch pressure gauge, bleed each rad, top up between rounds.