Drainage 4 min read Updated 14 March 2026 Trade verified

How to Fit an Air Admittance Valve — UK Trade Guide

An AAV lets air into your drainage without letting sewer gas out. Fitted at the top of a soil stack or under a hidden basin. Here is the compliant UK method.

Need parts for this job?
Trade-priced air admittance valve in the Plumber.Parts catalog — next-day delivery.
Shop parts

Step-by-step method

1. Choose the right AAV size

32/40mm for a single sink/basin. 82/110mm for a full soil stack. McAlpine MRAA and Durgo are the UK go-tos.

2. Position above the highest branch

Must be at least 200mm above the top waste branch entering the stack — otherwise it will get flooded.

3. Ventilated space

Loft installation needs a warmed roof space or the valve seizes in winter. Alternatively fit inside a boxed-in vent within the building envelope.

4. Solvent weld or push-fit

On 110mm soil pipe, use a strap-boss and solvent-weld boss adapter with the AAV on top. On 40mm waste, push-fit is fine.

Frequently asked questions

Are AAVs allowed under UK Building Regs?+

Yes — permitted under BS EN 12380 and Building Regs Part H. Cannot be the ONLY vent on a whole drainage system — main stack must terminate as an open vent OR AAV, but a secondary main vent is often required.

Can I replace an open vent with an AAV?+

On a single-dwelling stack, yes if the drainage system has adequate ventilation. Best to consult Building Control for anything complex.