Vaillant Fault Code F20 — Diagnose and Fix

Fault code F20 on a Vaillant boiler indicates no ignition. Gas valve opens but spark or flame detection fails. Here is the diagnostic order UK Gas Safe engineers follow.

Need parts for this job?
Trade-priced Vaillant PCB in the Plumber.Parts catalog — next-day delivery.
Shop parts

Step-by-step method

1. Confirm the F20 lockout

Power off at the fused spur for 60 seconds, restore and reset. If F20 returns within 5 minutes, proceed. Intermittent F20 points to a sensor or connection, not the PCB.

2. Check pressure, condensate, gas

System pressure 1.0–1.5 bar, condensate unfrozen, gas proven at another appliance — accounts for ~60% of lockouts.

3. Test what F20 points at

Gas valve opens but spark or flame detection fails.

4. Reset and prove

Reinstate covers (interlocks matter), reset and observe full ignition. Flame current 1–8 µA DC.

5. Gas Safe callout

Gas-side work on a Vaillant requires Gas Safe. Provide the fault code, GC number and serial so parts are pre-ordered.

Frequently asked questions

Reset Vaillant F20 myself?+

Hold reset 5 seconds. If it returns, fault is still present.

Repair cost?+

£120–£280 typical; PCBs £180–£320; sensors £60–£100.

Warranty cover?+

Yes if within warranty and annual services logged.